Manhole & separator test
Pressure test system for testing of manholes and/or liquid separators
- Test accuracy (10 hours) 0.1 mm
- LGA certificate BMW 0420285-01
With the temperature compensating relative pressure test sensor (0-40 mbar) a precise pressure test of separators in accordance with DIN 1999-100 is achieved.
Details:
Premus:
- Control unit for connection of maximum 3 sensors for level measurement of liquid separators and manholes
- Data acquisition and supply via USB
- Optionally upgradeable to include automatic water top up
- Control processor with RS232 interface to PC
- Connectors and armatures for level sensor
- Tripod, adjustable with holder for level sensor
- Premus upgrade pressure test with water
- Filling hose
Pressure transmitter:
- Level sensor in stainless steel
- Measuring range 0-300 mm (0-30 mbar)
- Measuring resolution 0,1 mm
- Accuracy 0,1 % FSO
- Output 4 - 20 mA
- Maximum acceptable excess pressure 1 bar
- Protection IP 68
- Connection with 10 m cable with pressure balancing cable
Documentation:
- Notebook
- Printer
- Software for manhole and liquid separator test